MIL-STD-1399-3008
b. For user equipment on the filtered, regulated AGD systems aboard SSN 774 Class ships, the user equipment should be tested for 3 minutes at the following voltages:
550 VDC on 440 Vrms AGD systems: 440 Vrms x 1.414 x 1.200 + 505 VDC = 1252 V
150 VDC on 115 Vrms AGD systems: 115 Vrms x 1.414 x 1.200 + 155 VDC = 350 V
Equipment and system manufacturers should be aware of the end use of their products to ensure that the design is capable of withstanding the AGD voltage levels associated with their end application.
Custodian: Preparing activity: Navy - SH Navy - SH
(Project 1990-2008-001)
Review activities: Navy - OS, YD
NOTE: The activities listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at https://assist.daps.dla.mil.