MIL-STD-1399-3008
TA8LE I. Characteristics of shipboard electric power systems. (NOTE: Characteristic percentages are defined in Section 3.)
Characteristics |
Type I |
Type II |
Type III |
Frequency |
|||
1. Nominal frequency |
60 Hz |
400 Hz |
400 Hz |
2. Frequency tolerance |
±3% (±5% for submarines) |
±5% |
±0.5% |
3. Frequency modulation |
0.5% |
0.5% |
0.5% |
4. Frequency transient tolerance |
±4% |
±4% |
±1% |
5. Worst case frequency excursion from nominal resulting from items 2, 3, and 4 combined, except under emergency conditions |
±5.5% |
±6.5% |
±1.5% |
6. Recovery time from items 4 or 5 |
2 seconds |
2 seconds |
0.25 second |
Voltage |
|||
7. Nominal user voltage |
440, 115, 115/200 Vrms |
440, 115 Vrms |
440, 115, 115/200 Vrms |
8. Line-to-line voltage unbalance |
3% (0.5% for 440 Vrms, 1% for 115 Vrms for submarines) |
3% |
2% |
9. User voltage tolerance |
|||
a. Average line-to-line voltage from nominal |
±5% |
±5% |
±2% |
b. Line-to-line voltage from nominal, including items 8 and 9.a |
±7% |
±7% |
±3% |
10. Voltage modulation |
2% |
2% |
1% |
11. Maximum departure voltage from nominal resulting from items 8, 9a, 9b, and 10 combined, except under transient or emergency conditions |
±8% |
±8% |
±4% |
12. Voltage transient tolerance |
±16% |
±16% |
±5% |
13. Worst case voltage excursion from nominal resulting from items 8, 9.a, 9.b, 10 and 12 combined, except under emergency conditions |
±20% |
±20% |
±5.5% |
14. Recovery time from item 12 or item 13 |
2 seconds |
2 seconds |
0.25 second |
15. Voltage spike (± peak value) |
2.5 kV (440 Vrms sys) 1.0 kV (115 Vrms sys) |
2.5 kV (440 Vrms sys) 1.0 kV (115 Vrms sys) |
2.5 kV (440 Vrms sys) 1.0 kV (115 Vrms sys) |
Waveform (voltage) |
|||
16. Maximum total harmonic distortion |
5% |
5% |
3% |
17. Maximum single harmonic |
3% |
3% |
2% |
18. Maximum deviation factor |
5% (3% for submarines) |
5% |
5% |
Emergency conditions |
|||
19. Frequency excursion |
-100% to +12% |
-100% to +12% |
-100% to +12% |
20. Duration of frequency excursion |
2 minutes |
2 minutes |
2 minutes |
21. Voltage excursion |
-100% to +35% |
-100% to +35% |
-100% to +35% |
22. Duration of voltage excursion |
|||
a. Upper limit (+35%) |
2 minutes |
0.17 second |
0.17 second |
b. Lower limit (-100%) |
2 minutes |
2 minutes |
2 minutes |